Uploaded image for project: 'Instrument control development'
  1. Instrument control development
  2. INSTRM-2855

pass SlitPositionError to Gen2

    XMLWordPrintable

    Details

      Description

      When scienceObject exposure failed due to the slit position (see below), no error message was raised.  It is helpful to pass this error to Gen2 / observers.

      2026-01-19 05:11:36.351Z cmds 20 CommandLink.py:122 > 2 2559 w subCommand=58934,0,"sps expose object exptime=675.0 cams=b1,r1,n1,b2,r2,n2,b3,r3,n3,b4,r4,n4 doScien
       ceCheck visit=138379 metadata=0x257635dd484236b3,\"SSP_CO_Autumn_1h_46_v2\",138377,58934,-9999,\"no available value\",\"scienceObject\",\"SSP_CO_Autumn_1h_46_v2\",\"brn arm\""
       ,1,"SlitPositionError(sm4=ditherFib+0.2pix)"
       2026-01-19 05:11:36.351Z cmds 20 CommandLink.py:122 > 2 2559 i subCommand=58934,1,"sps expose object exptime=675.0 cams=b1,r1,n1,b2,r2,n2,b3,r3,n3,b4,r4,n4 doScien
       ceCheck visit=-1",2,"cancelled"
       2026-01-19 05:11:36.351Z cmds 20 CommandLink.py:122 > 2 2559 i sequence=58934,None,scienceObject,"SSP_CO_Autumn_1h_46_v2","brn arm","iic scienceObject exptime=675.
       0 duplicate=2 cam=all returnWhenShutterClose",failed,"SpsExpose(SlitPositionError(sm4=ditherFib+0.2pix))"
       2026-01-19 05:11:36.446Z DB-opdb 20 db.py:667 Starting insert of 1 rows into table 'iic_sequence_status'...
       2026-01-19 05:11:36.454Z DB-opdb 20 db.py:681 Successfully inserted 1 rows into 'iic_sequence_status' in 0.01 seconds.
       2026-01-19 05:11:36.454Z cmds 20 CommandLink.py:122 > 2 2559 f text="SpsExpose(SlitPositionError(sm4=ditherFib+0.2pix))"

        Attachments

          Activity

            People

            • Assignee:
              arnaud.lefur arnaud.lefur
              Reporter:
              yuki.moritani yuki.moritani
            • Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

              • Created:
                Updated: