Uploaded image for project: 'DRP 2-D Pipeline'
  1. DRP 2-D Pipeline
  2. PIPE2D-1856

Turn badRefPixel.yaml and nirLinearity-$cam.fits into calibration products

    XMLWordPrintable

    Details

    • Type: Task
    • Status: Done (View Workflow)
    • Priority: Normal
    • Resolution: Done
    • Affects Version/s: None
    • Fix Version/s: None
    • Component/s: None
    • Labels:
    • Sprint:
      preRun29Jul2026

      Description

      Both badRefPixel.yaml and nirLinearity-$cam.fits are data files in the drp_pfs_data product, so selecting calibration versions is currently done by setting up eups versions.

      Turn the two into proper calibration products so that we can use the usual validity date handling along with CALIBRATION run chaining. This is especially important for cleanly handling the recent detector replacement in n2.

      This will require some accessor changes in isrTask.py

      I think the data files themselves can stay in the drp_pfs_data product, but that product should gain some installation scripts.

        Attachments

          Activity

            People

            • Assignee:
              cloomis cloomis
              Reporter:
              cloomis cloomis
            • Votes:
              0 Vote for this issue
              Watchers:
              1 Start watching this issue

              Dates

              • Created:
                Updated:
                Resolved: